TestEquity

EXTENDED FOR A LIMITED TIME: 10% Off Solder Wire & Bars on orders over $500 – Online Only Until 11/15 – Use Code SOLDER10

Hioki

Hioki DT4256 Digital Multimeter

Our Part #26382.1

Mfr Part #DT4256

Hioki DT4256
Hioki

Hioki DT4256 Digital Multimeter

Our Part #26382.1

Condition:New

Mfr Part #DT4256

$245.00EACH

  • 6000-Count display
  • Easy operation for speedy measurement
  • Display of multiple measurement parameters
  • Different models for different applications
    • DT4251: Replaced with DT4255
    • DT4252: High-precision DC voltage and 10A AC/DC measurements; offering a range of measurement capabilities
    • DT4253: Make temperature, DC current (mA/μA). Ideal for HVAC
  • CATIV 600V design for maximum safety
  • Three-year warranty

DT4251: Measure current with clamp sensors - no exposed current terminals ensure safety. Ideal for when measurement safety is the top priority.

  • No ‘A' terminal
  • Includes clamp sensor connection terminals* and voltage detector

DT4252: High precision 600mV DC range and wide array of measurement features for all applications. Great for those who require a range of measurement capabilities.

  • High precision 600mV range
  • 6A and 10A ranges

DT4253: Temperature, DC mA & μA ranges for instrumentation and HVAC. Ideal for users responsible for maintaining instrumentation, heating, ventilation, or air conditioning equipment.

  • 60μA to 60mA range
  • Includes temperature measurement

DT4254: voltage-only model that addresses the cause of short-circuits at the root by intentionally removing the current measurement terminals

  • 600.0 mV to 1500 VDC
  • 6.000 V to 1000 VAC

DT4255: Clamp-based current measurement to eliminate contact with energized parts

  • 600.0 mV to 1000 VDC
  • 10.00 A to 1000 A Clamp

DT4256: voltage, current, resistance, capacitance, frequency, continuity check, and diode test functionality

  • 600.0 mV to 1000 VDC
  • 10.00 A to 1000 A Clamp

DT4252DT4253DT4254DT4255DT4256
TRMSYesYesYesYesYes
DCV basic accuracy±0.3 %rdg. ±5 dgt.±0.3 %rdg. ±3 dgt.
DC voltage600mV to 1000V600mV to 1500V600mV to 1000V
DCA current6A to 10A60μA to 60mA

N/A

N/A60.00 mA to 10.00 A
ACA current6A to 10AN/AN/AN/A600.0 mA to 10.00 A
AC clamp*N/A10A to 1000AN/A10.00 A to 1000 A10.00 A to 1000 A
Resistance600Ω to 60MΩN/A600Ω to 60MΩ
TemperatureN/A-40°C to 400°C

N/A

Capacitance1μF to 10mFN/A1μF to 10mF
Frequency99Hz to 99kHz

Includes: L9207-10 Test lead, Instruction Manual, four (4) LR03 Alkaline batteries, and Holster (attached to the instrument, with a test lead holder.).

Brand: Hioki
Quote Required: No
$245.00EACH